5 disable/enable of external i/o signals (dio), Communication functions – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 299

Advertising
background image

14 - 20

14. COMMUNICATION FUNCTIONS

14.12.5 Disable/enable of external I/O signals (DIO)

Inputs can be disabled independently of the external I/O signal ON/OFF. When inputs are disabled, the
input signals are recognized as follows. Among the external input signals, EMG, LSP and LSN cannot be
disabled.

Signal

Status

External input signals (DI)

OFF

External analog input signals

0V

Pulse train inputs

None

(1) Disabling/enabling the external input signals (DI), external analog input signals and pulse train

inputs with the exception of EMG, LSP and LSN.
Transmit the following communication commands:
(a) Disable

Command

Data No.

Data

[9][0]

[0][0]

1EA5

(b) Enable

Command

Data No.

Data

[9][0]

[1][0]

1EA5

(2) Disabling/enabling the external output signals (DO)

Transmit the following communication commands:
(a) Disable

Command

Data No.

Data

[9][0]

[0][3]

1EA5

(b) Enable

Command

Data No.

Data

[9][0]

[1][3]

1EA5

Advertising