Absolute position detection system, 1 outline, 1 features – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 308: 2 restrictions, Absolute position detection system caution

Advertising
background image

15 - 1

15. ABSOLUTE POSITION DETECTION SYSTEM

15. ABSOLUTE POSITION DETECTION SYSTEM

CAUTION

If an absolute position erase alarm (AL.25) or an absoluto position counter marning

(AL.E3) has occurred, always perform home position setting again. Not doing so

can cause runaway.

POINT

When configuring an absolute position detection system using the QD75P/D

PLC, refer to the Type QD75P/QD75D Positioning Module User's Manual

QD75P1/QD75P2/QD75P4, QD75D1/QD75D2/QD75D4 (SH (NA) 080058).

15.1 Outline

15.1.1 Features

For normal operation, as shown below, the encoder consists of a detector designed to detect a position
within one revolution and a cumulative revolution counter designed to detect the number of revolutions.
The absolute position detection system always detects the absolute position of the machine and keeps it
battery-backed, independently of whether the general-purpose programming controller power is on or off.
Therefore, once the home position is defined at the time of machine installation, home position return is
not needed when power is switched on thereafter.
If a power failure or a fault occurs, restoration is easy.
Also, the absolute position data, which is battery-backed by the super capacitor in the encoder, can be
retained within the specified period (cumulative revolution counter value retaining time) if the cable is
unplugged or broken.

LSO
1XO

MR-BAT

CPU

General purpose programmable
controller

Servo amplifier

Pulse train

(command)

Changi

ng t

h

e

curr

en

t p

o

si

ti

o

n

dat

a

Positioning module

I/O module

Current

position

data

Input

Output

Home position data

EEPROM memory

Backed up in the
case of power failure

Current

position

data

Detecting the
number of
revolutions

LS

1X

Detecting the
position within
one revolution

P

o

si

ti

on

c

o

nt

rol

S

p

e

e

d

cont

ro

l

Servo motor

1 pulse/rev Accumulative
revolution counter

Super capacitor

Within-one-revolution counter

(Position detector)

High speed serial
communication

Battery

15.1.2 Restrictions

The absolute position detection system cannot be configured under the following conditions. Test
operation cannot be performed in the absolute position detection system, either. To perform test
operation, choose incremental in parameter No.1.
(1) Speed control mode, torque control mode.
(2) Control switch-over mode (position/speed, speed/torque, torque/position).
(3) Stroke-less coordinate system, e.g. rotary shaft, infinitely long positioning.
(4) Changing of electronic gear after home position setting.
(5) Use of alarm code output.

Advertising