2 transfer method, Absolute position detection system – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 315

Advertising
background image

15 - 8

15. ABSOLUTE POSITION DETECTION SYSTEM

15.7.2 Transfer method

The sequence in which the base circuit is turned ON (servo-on) when it is in the OFF state due to the
servo-on (SON) going OFF, an emergency stop (EMG), or alarm (ALM), is explained below. In the
absolute position detection system, every time the servo-on (SON) is turned on, the ABS transfer mode
(ABSM) should always be turned on to read the current position in the servo amplifier to the controller.
The servo amplifier transmits to the controller the current position latched when the ABS transfer mode
(ABSM) switches from OFF to ON. At the same time, this data is set as a position command value inside
the servo amplifier. Unless the ABS transfer mode (ABSM) is turned ON, the base circuit cannot be
turned ON.
(1) At power-on

(a) Timing chart

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

80[ms]

80[ms]

1)

2), 3)

Power
supply

Servo-on
(SON)

4)
ABS transfer mode
(ABSM)

ABS request
(ABSR)

Send data ready
(TLC)

Transmission
(ABS) data

Base circuit

Ready
(RD)

If SON is turned ON before ABSM is input

During transfer of ABS

During transfer of ABS

(Note)

(Note)

(Note)

(Note)

(Note)

(Note)

ABS data

ABS data

Operation

enabled

Operation

enabled

Note. For details, refer to (1) (b) in this section.

D01:bit1
ZSP:bit2

Advertising