3 home position setting, Absolute position detection system – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 324

Advertising
background image

15 - 17

15. ABSOLUTE POSITION DETECTION SYSTEM

15.7.3 Home position setting

(1) Dog type home position return

Preset a home position return creep speed at which the machine will not be given impact. On detection
of a zero pulse, the home position setting (CR) is turned from off to on. At the same time, the servo
amplifier clears the droop pulses, comes to a sudden stop, and stores the stop position into the non-
volatile memory as the home position ABS data.
The home position setting (CR) should be turned on after it has been confirmed that the in-position
(D01 or INP) is on. If this condition is not satisfied, the home position setting warning (AL.96) will
occur, but that warning will be reset automatically by making home position return correctly.
The number of home position setting times is limited to 1,000,000 times.

OFF

ON

OFF

ON

OFF

ON

Servo Motor

Dog signal
(DOG)

Completion of
positioning
(D01 or INP)

Home position
setting (CR)

Home position
ABS data

Near-zero point dog

20 [ms] or more

20 [ms] or more

Update

Advertising