3 keep out foreign materials, Installation – MITSUBISHI ELECTRIC MELSERVO MR-J2S- A User Manual

Page 46

Advertising
background image

2 - 3

2. INSTALLATION

(2) Installation of two or more servo amplifiers

Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.

Control box

30mm
(1.2 in.)
or more

30mm
(1.2 in.)
or more

10mm
(0.4 in.)
or more

40mm
(1.6 in.)
or more

100mm
(4.0 in.)
or more

Servo
amplifier

(3) Others

When using heat generating equipment such as the regenerative brake option, install them with full
consideration of heat generation so that the servo amplifier is not affected.
Install the servo amplifier on a perpendicular wall in the correct vertical direction.

2.3 Keep out foreign materials

(1) When installing the unit in a control box, prevent drill chips and wire fragments from entering the

servo amplifier.

(2) Prevent oil, water, metallic dust, etc. from entering the servo amplifier through openings in the control

box or a fan installed on the ceiling.

(3) When installing the control box in a place where there are much toxic gas, dirt and dust, conduct an

air purge (force clean air into the control box from outside to make the internal pressure higher than
the external pressure) to prevent such materials from entering the control box.

Advertising