COMMUNICATIONS
SERIAL

5.

Press the Select key to enter the Serial menu, then press the
Next key until the message window displays

SERIAL
BAUD RATE

6.

Press the Select key to enter the Baud Rate menu. The message
window displays the currently selected baud rate (* represents
a default setting):

*9600 BAUD

7.

Press the Next key until the correct baud rate is displayed.

NOTE: Baud rates of 19200 and 38400 require that either RTS

or CTS hardware flow control (Hdwe Flow Ctl) be
selected. These baud rates do not support XON/XOFF
software flow control (Rcv Sw Flow CTL).

8.

Press the Select key. The message window momentarily
displays

RATE
IS SELECTED

(where

RATE

is the baud rate you selected) and then

SERIAL
BAUD RATE

9.

If you want to change other settings, use the Next key to scroll
to the setting you want to change, then repeat the procedure
described in steps 6 through 8 for finding and selecting new
settings.

When you have finished making changes, press the
Online/Offline key. The message window displays

Chapter 3

C o n n e c t i n g t h e P r i n t e r

3 - 2 1