SMC Networks ARM PL241 User Manual

Page 59

Advertising
background image

Functional Overview

ARM DDI 0389B

Copyright © 2006 ARM Limited. All rights reserved.

2-39

For t

WC

:

when using memory devices that are not wait-enabled, you must program t

WC

to

be the number of clock cycles required before the first data is written, following
the assertion of cs_n

when using memory devices that are wait-enabled, you must program t

WC

to be

the number of clock cycles required before wait is active and stable, following the
assertion of cs_n. That is:

t_WC = 3

Note

If a memory device is configured so that there are two or less clock cycles
between the assertion of wait and data being required then you must program t

WC

as if the memory device is not wait-enabled.

Advertising
This manual is related to the following products: