Siemens Simotion A4027118-A0414 User Manual

Page 105

Advertising
background image

Section E: Appendix

Error messages

Flying Saw with SIMOTION

A4027118-A0414

V 1.4

Release 06/06/08

105/107

C

opyr

ight

©

Si

em

ens

AG 2

0

08

Al

l r

ights r

e

s

e

rv

ed

M

anual_

S

IM

OTION Fl

ying Saw

_

V1

.4.

d

oc

ErrorID

error code

Explanation

C091

Manual to Disable
Error when stopping the FlyingSawAxis ( move mit v=0)
Details in FS_Var structure under RetDINT_stop_FSA

C092

Manual to Disable
Error when stopping the FlyingSawAxis ( move mit v=0)
Details in FS_Var structure under FR_stop_FSA

C0A1

Manual to Starting position
Error when positioning the FlyingSawAxis ( _pos )
Details in FS_Var structure under RetDINT_pos_FSA

C0A2

Manual to Starting position
Error when positioning the FlyingSawAxis ( _pos )
Details in FS_Var structure under FR_pos_FSA

C0F1

Incorrect mode selection from “error” mode

C0F2

Incorrect mode selection from “disable” mode

C0F3

Incorrect mode selection from “starting position” mode

C0F4

Incorrect mode selection from “automatic” mode

C0F5

Incorrect mode selection from “manual” mode

C101

Parameterizing error at the flying saw axis
Axis is not parameterized as synchronous axis.

C201

Parameterizing error at the material axis/external encoder
The material master (leading) value is neither a positioning axis
nor an external encoder

Advertising