Siemens Simotion A4027118-A0414 User Manual

Page 84

Advertising
background image

Section C: Integrating the core “flying saw” functions

Using the "FB_BGD_TEMPLATE_FlyingSaw()"

Flying Saw with SIMOTION

A4027118-A0414

V 1.4

Release 06/06/08

84/107

C

opyr

ight

©

Si

em

ens

AG 2

0

08

Al

l r

ights r

e

s

e

rv

ed

M

anual_

S

IM

OTION Fl

ying Saw

_

V1

.4.

d

oc

Fig. 8-3 Block outputs for fault messages

FB_BGD_TEMPLATE_FlyingSaw()

Execute

Mode

Done

Busy

Error

ErrorID

State

StopCutting

Gap

OnTheSpotCut

Cut

OnTheSpotCutPossible

OnTheSpotCutDone

IN

OUT

KnifeOut

The error bit signals an error while an error code is output at output
ErrorID

; this can be analyzed using the error analysis function.

A list of the possible error codes with a description of the error causes is
provided in the Appendix of this document, Chapter 12.2.

Note

The error output is only set if the execute input is set. The ErrorID and
state 0

are still output even after execute has been reset!