Section C: Integrating the core “flying saw” functions

Using the "FB_BGD_TEMPLATE_FlyingSaw()"

Flying Saw with SIMOTION

A4027118-A0414

V 1.4

Release 06/06/08

82/107

C

opyr

ight

©

Si

em

ens

AG 2

0

08

Al

l r

ights r

e

s

e

rv

ed

M

anual_

S

IM

OTION Fl

ying Saw

_

V1

.4.

d

oc

Fig. 8-1 Possible state transitions at the "FB_BGD_TEMPLATE_FlyingSaw()"

1

Disable

1

Disable

2

Startposi-

tion

2

Startposi-

tion

4

Manual

4

Manual

0

Error

0

Error

3

Automa-

tic

3

Automa-

tic

Standard Zustandsübergang

Fehlerzustandsübergang

Automatische Zustandswechselkette

RESTART

The actual block state is displayed at the state output.

Fig. 8-2 Inputs and outputs of the mode changeover

FB_BGD_TEMPLATE_FlyingSaw()

Execute

Mode

Done

Busy

Error

ErrorID

State

StopCutting

Gap

OnTheSpotCut

Cut

OnTheSpotCutPossible

OnTheSpotCutDone

IN

OUT

KnifeOut

Changing-over the mode

In order to transition the block into a new state, the number of the required
target state must be specified at the mode input. The changeover is
activated using a high signal at Execute input. The block signals the active
changeover into the new state using a high signal at the Busy output. If all
of the actions associated with the changeover have been successfully