Standard operator control

Table 5-3: Standard operator control in the automatic mode

No.

Action

Comment

1 Initial situation:

The “flying saw” is in the AUTOMATIC-STOPPED mode

2 Using the Sync Position slider switch, enter the position

at which the flying saw reaches the position where the
material web is to be cut.

3 The flying saw starts to move to the starting position by

pressing the Flying Saw STARTPOS button

4 After the starting position has been reached, the flying

saw is in the AUTOMATIC-READY mode

5 The flying saw is enabled for operation using the Flying

Saw START button.

6 The flying saw is in the AUTOMATIC-STANDBY mode

and waits for material.

7 Select the required material web velocity using the

Material Velocity slider.