Section B: The application example as demonstration

system

I

t lli

th h d

d

ft

Flying Saw with SIMOTION

A4027118-A0414

V 1.4

Release 06/06/08

32/107

C

opyr

ight

©

Si

em

ens

AG 2

0

08

Al

l r

ights r

e

s

e

rv

ed

M

anual_

S

IM

OTION Fl

ying Saw

_

V1

.4.

d

oc

4.4.4

Setting the Ethernet interface of the PG/PC

Setting the PG/PC interface

Table 3-5: Setting the PG/PC interface

No.

Action

Comment

1 In SIMOTION SCOUT open the interface

configuration using O

PTIONS

Æ S

ET

PG/PC

INTERFACE

...

2 In the “Interface Parameter Assignment

Used” area, select your Ethernet
card/interface of the PG/PC using the
interface setting “TCP/IP

Æ ......”.

(e.g. "TCP/IP

Æ VIA PCI 10/100 Fast

Ethernet Adapter“)

3 Acknowledge (possible) warning with

Yes.

4

Acknowledge your change with OK

5 Now return to SIMOTION SCOUT and

open the network configuration

NETPRO using the button or the

menu P

ROJECT

Æ O

PEN

N

ET

P

RO

.