3 environmental limits, 4 cable requirements, 5 rings and tones – Samsung OFFICESERV 7100 User Manual

Page 28: 1 ring cycles, 1a system ring cycles, Environmental limits, Cable requirements, Ring and tones, 5 rings and tones 3.5.1 ring cycles

Advertising
background image

*This the maximum distance a door phone can be from the DPIM. The DPIM can be up to 900 cable feet from the
KSU. The total distance must not exceed 1230 feet.

3.5 RINGS AND TONES

3.5.1 RING CYCLES

The OfficeServ 7100 provides the trunk line rings, station rings, door rings, and alarm rings. The ON/OFF cycle of
each ring is shown in the table below (it is different according to the country, and can be modified by MMC pro-
gramming).

Note: The ON/OFF cycle can be adjusted by changing the values of the system database.

3.2

3.3 ENVIRONMENTAL LIMITS

OPERATING TEMPERATURE

32—113 °F / 0—45 °C

STORAGE TEMPERATURE

14—122 °F / --10—50 °C

HUMIDITY

10%—90% Non-Condensing

3.4 CABLE REQUIREMENTS

EQUIPMENT

CABLE

AWG

MAX FEET

MAX METERS

DIGITAL KEYSET

1 PR. TWISTED

24

1300

400

ADD-ON MODULE

1 PR. TWISTED

24

1300

400

SINGLE LINE STATION

1 PR. TWISTED

24

3000

1 KM

DOOR PHONE

2 PR. TWISTED

24

330*

100

3.5.1a SYSTEM RING CYCLES

RING

ON/OFF CYCLE

TRUNK LINE RING

1000/2000 ms

STATION RING

400/200/400/3000 ms

DOOR RING

400/200/400/200/400/2000 ms

ALARM RING

400/200/400/200/400/200/400/1000 ms