background image

Simrad AP50 Autopilot

102

20221032B

RFC35 Fluxgate Compass

The RFC35 Fluxgate Compass can be connected to the J50
Junction Unit, but the compass is not recommended for
commercial use.

RFC35

FLUXGATE

COMPASS

JUNCTION UNIT

MAIN PCB

Heading

Sensor

*

* NON POLARIZED

(COLOR INDEPENDENT)

HS
+

HS-

Figure 4-28 RFC35 connection

• Change in the Installation Interface menu: Select FLUX =

J50-HS.

4.13 FU50 Steering Lever

For connection of the FU50 Steering Lever, see the FU50
manual.

4.14 TI50 Thruster Interface

The TI50 Thruster Interface is designed to provide control signal
for operating one thruster in an AP50 system by either on/off
solenoid, continuous control, or Danfoss PVEM valve.
Refer to separate manual for the TI50 Thruster Interface.

4.15 AD50 Analog Drive

The AD50 Analog Drive is designed to provide analog or
proportional control of a rudder in an AP50 system by either
continuous voltage, or Danfoss PVEM valve signal.
Refer to separate manual for the AD50 Analog Drive.