Auto mode – Simrad AUTOPILOT SYSTEM AP50 User Manual

Page 43

Advertising
background image

Operation

20221032B

41

AUTO Mode

341°
CTS

340.7

Gyro1

SETUP

Move : ,
Adjust :

Backlight
Contrast
Steering function
Rudder
Seastate AUTO
Rudder 0.50
Count rudder 1.40

More

A

Backlight
Same procedure as in STANDBY mode.
Contrast
Same procedure as in STANDBY mode.

Steering Function
(only available if Thruster is selected in the Installation
Dockside Menu, see page 126).
Same procedure as in STANDBY mode.
Seastate
Seastate determines the number of degrees the vessel may fall
off the set course before any response is given to the rudder.
Select the value for the Seastate filter:
OFF:

Provides precise steering but increases rudder
activity.

AUTO:

Automatically reduces the rudder activity and
sensitivity of the autopilot in rough weather.

MANUAL: Sets yaw band manually (MAN 1 - MAN 10, 10

±6°).

This setting determines the number of degrees the vessel may
deviate from the set course before any command is given to the
rudder. In calm weather, it should be set to “OFF”, which means
that theoretically, the autopilot allows no deviation from the set
course. The Seastate filter value should be increased with
increasing sea turbulence. This will cause the sensitivity of the
rudder to be decreased such that the vessel has to deviate from
the set course by the number of degrees selected in the Seastate
filter setting before a rudder command is given. The amount of
rudder is calculated by the heading error exceeding the set limit,
multiplied by the p-factor. This will prevent excessive rudder
movement and reduce rudder activity.

Note !

In conditions where active steering is required, the Seastate
filter value should be reduced.