CD109 Course Detector
For retrofit installations a CD109 Course detector may be
connected to the CI300X according to Figure 4-43:

Vref

SIN

HI

LO

COS

MA

GN.

COM

P

MAGNETIC COMPASS
WITH CD109 COURSE
DETECTOR

TB1

10

13

12

11

9

SIN

COS

Vref

HI
LO

9

10

11

12

13

9

10
11

12

13

PLUG

Figure 4-43 CD109 connections to CI300X

CD100A Course Detector

The owner may prefer to use the boat’s own compass. The
compass must be fully gimbaled and have a flat surface
underneath to fit the CD100A. Make a hole for a 6 mm screw in
the bottom of the compass and mount the CD100A as shown in
Figure 4-44. Secure the 6 mm screw through the center hole of
the CD100A. Make sure the cable does not prevent the compass
from moving freely in the gimbals.

1 Screw M6x25mm, non

magnetic

2 Washer,

non

magnetic

3 Course

detector

4 Cable clamp, nylon

5 Washer,

non

magnetic

6 Screw M3x10mm, non

magnetic

3

2

1

4

5

6

Note!

Lock nut on mounting screw (pos.
1) for transportation only. To be
removed before mounting.


When the course detector is
mounted on a reflector compass,
use the tripod holder (ref. to
Figure 3-6 on page 55).

Figure 4-44 CD100A Course Detector Mounting