Display readout

Probable fault Recommended

action

No rudder response
(Remains in actual
mode without any
rudder command)

− Steering gear not

operative

− Broken connection
− Missing power
− Defective electronics

1. Check all connections.
2. Check Rudder FB transmission

link, steering gear, and change
over switches.

3. Check the drive unit motor/

brushes and bypass
valve/clutch.

For solenoid drive:
4. Check LEDs for command from

galvanic isolated solenoid
electronics (ref. page 86).

5. Replace the junction unit Power

PCB.

6. Check the jumper switch (S1)

setting on J50 Power PCB.

For Analog or Proportional drive:
7. Check that the AD50 is

operative (ref. separate manual
for AD50).

Rudder too slow

Excessive load on
steering gear, air in the
hydraulic system or
insufficient drive unit
capacity.

1. Look for mechanical

obstructions at the
rudder/tiller/quadrant. Check
the back drive force.

2. Bleed the hydraulic system.
3. Replace with a bigger pump

unit.

Rudder test failed

The following conditions
may exist:
a) Rudder feedback

failure.

b) J50 current overload.
c) Bypass/clutch

overload.

Refer to the recommended actions
for the specific probable faults.

Rudder moves in only
one direction

a) Poor connection to

one of the solenoids
(continuously
running pump).

b) Faulty Power PCB

in junction unit.

a) Check the connections
b) Replace the junction unit Power

PCB

Advertising