R3000x remote control, S100 nfu lever installation, Junction unit – Simrad AUTOPILOT SYSTEM AP50 User Manual

Page 105: Installation

Advertising
background image

Installation

20221032B

103

4.16 R3000X Remote Control

The R3000X Remote Control is weather proof and can be
mounted outdoors in the supplied bracket that is fixed by four
mounting screws.

G n R ed Blu

R E M O T E

R3000X

REMOTE CONTROL

Yel

JUNCTION UNIT

POWER PCB

TB1

TB2

TB3

TB5

Lamp

St

bd

Po
rt

Gn
d

REMO TE

TB4

Figure 4-29 R3000X Remote Control Connection

4.17 S100 NFU Lever Installation

The S100 Steering Lever is for indoor mounting in panels up to 8
mm (5/16 in.) thick. The handle must be removed from the unit
before mounting. A 22 mm (7/8 in.) hole should be cut in the
panel. The S100 is supplied with 10 m (33 ft.) of cable. Connect
the wires to the junction unit power PCB as shown. If the
direction of rudder movement (Port/Stbd) is in the wrong
direction when operating the steering lever, rotate the unit 180°.
For cable extension, a suitable extension cable and junction box
or terminal should be provided locally.

Gn R ed Blu

R E M O T E

Yel

JUNCTION UNIT

POWER PCB

TB1

TB2

TB3

TB5

St

bd

Po
rt

Gn
d

R EMOTE

TB4

S100

NFU

STEERING LEVER

Figure 4-30 S100 NFU Lever Connection

Advertising