Installation

20221032B

97

See Table 4-5 for pin configuration and color code of the
network cable. DO NOT MIX THE PINS AND THE CABLE
COLORS!

Note !

Apply a thin layer of pure Vaseline (petroleum jelly) on the
connector threads and make sure the connectors are properly
secured to the receptacle by the coupling ring. When properly
installed, the connectors are weatherproof according to IP56.
All unused RobNet plugs must be fitted with plastic caps to keep
the connectors free of dirt and moisture. A separate screw cap
for the control unit is included in the installation kit.

Cable

pairs

Color

code

Pin Signal

1

st

pair Pink

5 V

SYSTEM+

Grey

4

V

SYSTEM–

2

nd

pair Brown

1

Bus–

White

2

Bus+

3

rd

pair Yellow

3

On - Off

5

4

2

1

6

FRONT VIEW

3

Green

6

ALARM

Table 4-5 RobNet Plug Pin Configuration

On
-O

ff

Vs
ys

+

JUNCTION UNIT

MAIN PCB

ROBNET

Bu
s+

Vs
ys

Ala
rm

Wh

Bn

Gn

Bu
s

Pnk Gry Yel

AP50

CONTROL

UNIT

Figure 4-23 Control Unit Connection

Note !

For installations that require special cable lengths, contact your
Simrad distributor for information.