Troubleshooting

20221032B

167

Display readout

Probable fault Recommended

action

Rudder test failed
(continued)

Rudder test not
completed within 2 min.
a) Poor connections to

the drive unit.

b) Faulty Main PCB in

the junction unit.

c) Faulty Power PCB in

junction unit.

a) Check the connections.
b) Replace the Main PCB
c) Check the Power PCB for traces

of burned transistors. – Change
Power PCB.

Rudder moves at full
speed to one side.
a) Faulty Power PCB in

junction unit.

Replace the junction unit Power
PCB

Steering compass
missing

Monitor compass
missing

No data from the selected
compass.

1. If more that one compass is

connected to the system, refer to
the User Set-up menu to select a
different compass.

2. Check the connections and the

Interface menu for proper set-up.

3. Service appropriate compass.

Failure active
Control Unit

Active control unit goes
silent.

1. Press the STBY button on an

"Inactive" unit to reset.

2. Check/repair the RobNet cable.
3. Replace the control unit PCB.

J50 current
overload
(Remains in actual
mode without any
rudder command)

The drive unit shut down
due to an excessive load
or a short circuit.

1. Check the drive unit and drive

unit installation.

2. Disconnect the drive unit. If the

fault is still present, replace the
junction unit Power PCB.

J50 Internal
Voltage

Internal 15 V supply in
junction unit is below the
limit.

1. Replace the junction unit Main

PCB.

2. Replace the junction unit Power

PCB if Mains voltage is 12V.

J50 high temp.

Excessive temperature in
the junction unit
(>75°C), possible long
term overload.

1. Switch off the autopilot.
2. Check for backload in the drive

unit/steering system.

3. Check that the junction unit

specifications match those of
the drive unit.