Advanced Settings

20221032B

145

6 ADVANCED SETTINGS

6.1 Service Menu

Select STANDBY mode and then enter the Installation Menu by
pressing and holding the NAV/SETUP button for 5 seconds.
Select "SERVICE" by pressing the (STBD) button and
confirm by rotating the course knob clockwise.

SYSTEM DATA

NMEA DATA

NMEA PORT TEST
Master reset?

No

Yes

“SYSTEM DATA” and “NMEA DATA” are test functions to
analyze data processed by the AP50.
To exit the menu, press any mode key (STBY, AUTO or NAV).

System Data

SYSTEM DATA

Steer compass 220.0°M

Monitor comp. 225.2°

Rudder P 03.07

Steer Course 240°

System Filter Values

WAVES Fc: 05s Db:04°

Input voltage 11V

Drive out 100%

Clutch/bypass

installed

FUV1R2

Select "SYSTEM DATA” by rotating the course knob
clockwise. This menu provides you with additional system data
that can be useful when testing or trouble shooting the system.
Steer compass
Steering Compass readout, M=Magnetic, T = True.

Monitor comp.
Monitor Compass readout.
Rudder
Rudder angle. Normally between 0 and 45°.
Steer Course
Current steered course in AUTO and NAV modes.
System Filter Values
Values set by the automatic sea state filter (in AUTO and NAV
modes).

Fc = Wave filter time constant in seconds.
Db = Deadband in degrees to each side of the set course. The

boat has to be outside the deadband before the autopilot
responds.

Input voltage
Mains voltage on input terminals.
Drive out
Power needed to drive the unit (in percent of full [100%]) to get
satisfactory rudder speed. (Refer to page 151 for adjustment).