Single nmea input/output, Junction unit, Installation – Simrad AUTOPILOT SYSTEM AP50 User Manual

Page 107: Figure 4-33 single nmea connection

Advertising
background image

Installation

20221032B

105

4.20 Interfacing to Optional Equipment (THD,

Navigation Receiver, etc.)

With the AP50 autopilot system, there are several options for
connection to other equipment for data exchange:
1. The J50 Junction Unit includes two NMEA input/output ports

and a Clock Data heading interface to Simrad and Furuno
radars. Only the J50-2 port (NMEA input 2) accepts NMEA
heading sentences.

2. The optional NI300X NMEA Interface (expansion) Unit

includes 4 additional NMEA input/output ports.

The following connecting diagrams illustrate the interfacing
possibilities.

Note !

See also “Interface Set-up” page 126 and the NMEA sentence
table page 68.

Single NMEA input/output

RX
1

RX
1+

MAIN PCB

NMEA Input 1

Vb
a

t+

S

ys.

se
l.

Gn
d

TX
1

TX
1

+

NMEA

Output1

NMEA listener

NAV RECEIVER

OR PLOTTER

(NMEA talker)

JUNCTION UNIT

RUDDER instr.
COMPASS instr.
RADAR

TB13

TB14

Figure 4-33 Single NMEA Connection