W seastate, W rudder, W count rudder – Simrad AUTOPILOT SYSTEM AP50 User Manual

Page 154: Counter rudder, W seastate w rudder w count rudder, W rudder limit cruising speed speed response

Advertising
background image

Simrad AP50 Autopilot

152

20221032B

Counter rudder
Counter Rudder is the parameter that counteracts for the effect
of the boats turn rate and inertia. The default value depends on
boat length.
Range: 0.05 to 8.00.

W Seastate

As for Seastate above but applies for the Work-modes.

W Rudder

As for Rudder above but applies for the Work-modes.

W Count rudder

As for Counter rudder above but applies for the Work-modes.

W Rudder limit
This determines the maximum rudder movement, in degrees
from the “used” midship position, that the autopilot can
command the rudder in the WORK modes.
Default: 10°.
The W Rudder limit setting is only active during AUTO-
WORK and NAV-WORK steering on straight courses, NOT
on course changes, but a Rudder Limit warning will be
shown during course changes.

Cruising speed
If the Cruising speed was not set during sea trial or needs to be
changed, it can be set manually here. Refer to page 138.
Range: 3 – 70 knots
Default: 15 knots

Speed response
This adjusts the value for the Speed response (see page 143).
Range: 0.00 – 2.00
Default: 0.00

Advertising