Option setting – Sanyo VCC-ZM400 User Manual

Page 60

Advertising
background image

OPTION SETTING

B

Color/black & white selection setting (DAY/NIGHT)

The ALARM IN terminal on the rear panel can be used to force
the image mode to color mode or black & white mode. Use this
setting when using this terminal to force the mode selection.
However, when this setting is being used, external alarm input
cannot be received.

1

Set DAY/NIGHT in the LENS setting screen to “COLOR”.

First change the DAY/NIGHT setting in the LENS setting screen
to “

COLOR”. (See p23)

2

Color/black & white selection setting

Use the cursor button (j or l) to move the cursor to
ALM for ALARM IN, and then use the cursor button (
d
or c) to set the input (e.g. COLOR).

ALM: The control terminal (ALARM IN) is used for alarm input.

COLOR: The control terminal (ALARM IN) is used for
color/black & white selection input. External operations can
then be used to forcibly switch the mode to color mode or
black & white mode.

3

POLARITY setting

Use the cursor button (j or l) to move the cursor to
POLARITY, then use the cursor button (
d or c) to select
“NO” or “NC”.

Available settings:

NO: Normally open (Normally open, and mode switches

between color and black & white when closed)

NC: Normally closed (Normally closed, and mode switches

between color and black & white when opened)

POLARITY setting

Between ALARM

IN - COM terminals

Mode after

selection

When set to NO

Open

COLOR

Closed

B/W

When set to NC

Open

COLOR

Closed

B/W

Note:

If DAY/NIGHT has been set to “

COLOR”, color/black &

white selection will not be possible.

If COLOR is selected, settings relating to external alarm
input will not be displayed, and it will not be possible to
receive external alarm inputs.

The color/black & white selection setting is applied from the
point after the menu is exited.

1

LENS

FOCUS MANU ‚

ZOOM SET ‚

DAY/NIGHT COLOR‚

VIEW ANGLE OFF

PRESET OFF
MENU BACK

2, 3

ALARM SETTING

ALARM IN ALM
POLARITY NO
MOTION OFF
DURATION 5S
ALARM OUT OFF
POLARITY NO
ALARM TIME 5S
LINE OUT OFF
PRESET OFF
MENU BACK

L5AD2/US (VCC-ZM400) GB 2003, 2, 4

En
g

lis

h

59