Examples: type and contents, Examples: type and contents of alert mail – Sanyo POA-MD13NET2 User Manual

Page 118

Advertising
background image

30

Chapter 3 Basic Setting and Operation

Examples: Type and contents of alert mail

When the projector has an abnormality, the following alert messages are sent to the
registered E-mail address according to your selected condition. Administrator or user
can take an efficient action quickly by receiving this massage. This is very useful to
maintain and service the projector.
The following are examples of received messages.

● When the internal temperature is too high:

● When the internal power circuit is failed:

● When the life span of lamp is reached:

✐ The Network Board let users know which thermal sensor [A] or [B] inside the projector

detected the abnormal rise in temperature and so the projector was turned off. Please refer
to item “Check the status of projector” for the location of the sensors [A] and [B], and tem-
perature (

☞ p.33). Also see the owner's manual of the projector for further details.

✐ Replace it with a new lamp immediately and reset the lamp counter. If the projector

is used without resetting the lamp counter, the alert mail is sent to users every time
the projector is turned on. This alert mail will not be sent when unchecking the mail
sending condition “When the life span of lamp is reached”.

TITLE: Message from projector
01-01-2001 00:59
Projector Model Name: XF30
TCP/IP: 192.168.0.2 Projector Name: myProjector

It sends you following massage.

*The Projector lamp is turned off, because internal projector temperature is too
high.

Wait Temperature Warning Indicator turned off,turn the Projector on again.
If the Indicator continues to flash,check the air filter for dust accumulation.

[A] 36.5 Degree [B] 58.2 Degree
Temperature of Sensor B is too high.

TITLE: Message from projector
01-01-2001 00:58
Projector Model Name: XF30
TCP/IP: 192.168.0.2 Projector Name: myProjector

It sends you following massage.

*The Projector lamp was turned off, because projector power circuit failed.

Unplug the projector from AC outlet and ask servicing to qualified service

personnel.
Information : FFFEFFFF

TITLE: Message from projector
01-01-2001 00:58
Projector Model Name: XF30
TCP/IP: 192.068.0.2 Projector Name: myProjector

It sends you following massage.

*The life span of lamp2 is reached.
Lamp2 replacement is required.
Lamp1 ON 350 h
Lamp2 ON 500 h
Lamp3 ON 60 h
Lamp4 ON 350h

✐ The Projector lamp was turned off, because the projector power circuit failed.

Unplug the projector from AC outlet and ask servicing to a qualified service personnel
with the information code “FFFEFFFF”.