10

Servicing should only be performed by a Qualified Service Agent

OPERATION AND SERvICE

how it worKs

This section of the manual will cover operation, common service procedures and water heater construction.

The water heater covered in this manual has a helical shaped coil heat exchanger that is submerged in

the storage tank. These water heaters use a top mounted down fired radial design Burner. This is a forced

draft burner; hot burning gases are forced through the heat exchanger under pressure and exit through the

exhaust/vent connection located at the bottom of the water heater.
Starting at the top air and fuel gas are drawn in by the Combustion Blower and Venturi, see Combustion

Blower on page 11 and Venturi on page 22. Flue gases and are forced through the helical shaped heat exchanger

by the Combustion Blower and out through the exhaust/vent outlet, see Figure 6 below.

BLOWER/BURNER

GAS VALVE

ASSEMBLY

COMBUSTION

AIR INTAKE

CONNECTION

HELICAL SHAPE

HEAT EXCHANGER

ARROWS SHOW

PATH OF FLUE

GASES THROUGH

THE HEAT

EXCHANGER

EXHAUST/VENT

OUTLET

INTERNAL VIEW

Figure 6