Introduction, Qualifications, Service warning – State Industries SHE50-100PE User Manual

Page 4: Service reminder, Tools required

Advertising
background image

2

Servicing should only be performed by a Qualified Service Agent

This Service Manual covers the water heater Model and Series numbers listed on the front cover only. The

instructions and illustrations contained in this manual will provide you with troubleshooting procedures to

verify proper operation and diagnose and repair common service problems.

Qualifications

Qualified installer or service agency
Installation and service of this water heater requires ability equivalent to that of a Qualified Agency (as defined

by AnSI below) in the field involved. Installation skills such as plumbing, air supply, venting, gas supply and

electrical supply are required in addition to electrical testing skills when performing service.
ansi Z223.1 2006 sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either

in person or through a representative is engaged in and is responsible for (a) the installation, testing or

replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and

equipment; that is experienced in such work; that is familiar with all precautions required; and that has

complied with all the requirements of the authority having jurisdiction.”

service warning

If you are not qualified (as defined by AnSI above) and licensed or certified as required by the authority

having jurisdiction to perform a given task do not attempt to perform any of the procedures described in

this manual. If you do not understand the instructions given in this manual do not attempt to perform any

procedures outlined in this manual.

service reminder

When performing any troubleshooting step outlined in this manual always consider the wiring and connectors

between components. Perform a close visual inspection of all wiring and connectors to and from a given

component before replacement. Ensure wires were stripped before being crimped in a wire connector, ensure

wires are crimped tightly in their connectors, ensure connection pins in sockets and plugs are not damaged

or worn, ensure plugs and sockets are mating properly and providing good contact.
Failure to perform this critical step or failing to perform this step thoroughly often results in needless down

time, unnecessary parts replacement, and customer dissatisfaction.

tools reQuired

• Instruction Manual that came with the water heater.
• All tools common to installation and service of commercial water heaters such as hand tools, torch, pipe

wrenches etc.

• Long (8-10”) T handle 1/8 inch hex (allen key) wrench for Combustion Blower removal and installation.
• Hex (Allen) wrench sizes: 5/32”, 1/8”, 1/4” and 5/16" - for Burner, and 24 Volt Gas Valve removal and

installation.

• Two digital manometers: Range -20.00 to +20.00" W.C. Resolution - 0.01" W.C. Recommend uEI model

EM200 or equivalent. Required to test pressure switch performance. Also used to measure supply and

manifold gas pressures.

• digital Multi Meter; Fieldpiece HS36, Fluke 187, uEI dL289 or equivalent capable of measuring:

• AC/dC Voltage.
• ohms.
• dC micro amps (μA) - flame sensing current, see Flame Sensing Current Test on page 19.

• AC amp meter- recommend uEI model dL289 or equivalent.
• 120 VAC plug in outlet tester, see Figure 2 on page 6

introduction

Advertising
This manual is related to the following products: