Control system monitoring, Blower prover failure, Blower prover open – State Industries SHE50-100PE User Manual

Page 31: Blocked air intake, Blocked exhaust

Advertising
background image

29

Servicing should only be performed by a Qualified Service Agent

control system monitoring
The Control System monitors the “state” of the pressure switch contacts individually through three separate

circuits, see Wiring diagram on page 44. The state of the switch refers to whether the switch contacts are open

or closed, see Construction & operation on page 28.
At the beginning of a heating sequence, before the Combustion Blower is energized, the Control System

enters the Input Verification operating state, see operating States on page 48. during Input Verification the

Control System monitors all three pressure switches to ensure their contacts are in the correct "normal"

state. The Blower Prover switch contacts must be open, the contacts for the Blocked Intake Air and Blocked

Exhaust switches must be closed, see Figure 30 on page 28 and the Sequence of operation on page 54.
If any of the pressure switch contacts are not in their correct normal state during Input Verification the Control

System will lock out and display a fault message on the LCd indicating which pressure switch caused the

fault condition, see Figure 31 below. If all system checks pass during the Input Verification operating state the

Control System enters the Pre-Purge operating state and energizes the Combustion Blower.
After the Combustion Blower is energized the Control System must confirm the Blower Prover switch contacts

have closed, see the Sequence of operation Flow Chart on page 55. The Blocked Intake Air and Blocked

Exhaust switch contacts must remain closed at all times.
If the Blower Prover switch contacts are closed during the Input Verification the Control System will lock out

and display Blower Prover Failure on the LCd. If the Blower Prover switch contacts do not close after the

Combustion Blower is energized the Control System will lock out and display Blower Prover Open on the

LCd. If either the Blocked Intake Air or Blocked Exhaust switch contacts open at any time during a heating

sequence the Control System will lock out and display Blocked Air Intake or Blocked Exhaust on the LCd.

See Figure 31 below.

CHANGE

BACK

ADVANCED

Blower Prover Failure

Fault occurred 2 mins ago

The blower prover switch is

closed out of sequence.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

CHANGE

BACK

ADVANCED

Blower Prover Open

Fault occurred 2 mins ago

The blower prover switch remains

open after the blower has been

energized.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

CHANGE

BACK

ADVANCED

Blocked Air Intake

Fault occurred 2 mins ago

The combustion air intake is

restricted.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

CHANGE

BACK

ADVANCED

Blocked Exhaust

Fault occurred 2 mins ago

The exhaust is blocked or

restricted. Ensure

condensate hose is draining.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

PRESSURE SWITCH FAULT MESSAGES

Figure 31

Advertising
This manual is related to the following products: