Eco continuity test – State Industries SHE50-100PE User Manual

Page 38

Advertising
background image

36

Servicing should only be performed by a Qualified Service Agent

TABlE 4

water temperature

temperature sensor

resistance in ohms

celsius

fahrenheit

40°

26,435

21°

70°

11,974

38°

100°

5,862

49°

120°

3,780

55°

130°

3,066

60°

140°

2,503

71°

160°

1,698

82°

180°

1,177

eco continuity test
1. Turn off power to the water heater at the water heater's on/off switch.
2. Remove the top cover on the water heater, see Figure 3 on page 8.
3. disconnect the four pin plug from the Temperature Probe outside the CCB enclosure on the left, see

Figure 35 below.

4. Ensure tank temperature is less than 100°F (38°C) - dump water to lower tank temperature if necessary.
5. using an ohm meter set the range for continuity testing.
6. Check continuity between the two outside pins (red wires) of the plug end from the Temperature Probe,

see Figure 35 below.

Results/Actions

• If the ohm meter shows continuity (closed circuit) between the two outside pins (red wires) the ECo

switch has reset properly. If the Control System continues to lock out displaying Energy Cut Out

(ECO) on the LCd with continuity through the ECo present call the toll free support phone number

listed on the back cover of this manual for further assistance.

• If the ohm meter shows no continuity (open circuit) between the two outside pins (red wires) and the

tank temperature is known to be at or below 100°F (38°C) - replace the Temperature Probe. Follow

the draining and filling instructions in the maintenance section of the Instruction Manual that came

with the water heater when replacing the Temperature Probe.

• If the Control System continues to lock out displaying Energy Cut Out (ECO) on the LCd and the

water temperature inside the water heater is becoming excessive (at or above 201°F/94°C) check

water system piping; ensure heat is not being added by any other heating appliances or heat sources.

If all these tests have been performed and the Control System continues to lock out call the toll free

support phone number listed on the back cover of this manual for further assistance.

Figure 35

Advertising
This manual is related to the following products: