Low igniter current, Fault messages – State Industries SHE50-100PE User Manual

Page 66

Advertising
background image

64

Servicing should only be performed by a Qualified Service Agent

fault messages

displayed message/condition/indicates

possible causes - checK/repair

low Igniter Current

The Control System has detected less than 0.5 AC amps

through the Igniter during the Igniter Warm up operating

state. See the Sequence of operation Flow Chart on

page 55.

CHANGE

BACK

ADVANCED

Low Igniter Current

Fault occurred 2 mins ago

Igniter current is low.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

Important Service Reminder:

When performing any troubleshooting steps outlined in

this manual always consider the wiring and connectors

between components. Perform a close visual inspection

of all wiring and connectors to a given component before

replacement.

• Check all wiring between CCB’s J5 Socket (page 41)

pins 1 & 2 and the Igniter. Repair/replace anything

worn or damaged as necessary.

• Check the Igniter wiring connections behind the CCB

enclosure. See Figure 10 on page 13 and Figure 21 on

page 21. Repair/replace anything worn or damaged as

necessary.

• Perform close visual inspection of the pins inside

the CCB J5 plug and socket - ensure plugs and

sockets are mating properly and providing good

contact Repair/replace anything worn or damaged as

necessary.

• With power turned on and a call for heat active -

ensure there is 120 VAC between pins 1 & 2 of

the CCB’s J5 Socket during the Igniter Warm up

operating state. - the animated lighting bolt icon will

appear on the desktop Screen during the Igniter

Warm up operating state. See desktop Screen on

page 46 and operating States on page 48.

• Turn off power to the water heater - disconnect the

Igniter wires from the Burner Adapter wiring harness

behind the CCB enclosure. Check for continuity

between the two Igniter wires, two female spade

connectors. If the Igniter is an open circuit or 200

ohms or more - replace the Igniter.

• With power turned on and a call for heat active -

check amp draw through the Igniter with an AC amp

meter during the Igniter Warm up operating state.

See the Igniter Current Test on page 20. Replace

Igniter if amp draw is less than 0.55 AC amps.

• Call the toll free support phone number on the back

cover of this manual for further assistance if the

problem has not been corrected after performing the

procedures outlined here.

Advertising
This manual is related to the following products: