State Industries SHE50-100PE User Manual

Page 45

Advertising
background image

43

Servicing should only be performed by a Qualified Service Agent

CCB CoNNECTIoN IDENTIFICATIoN (CoNT)
J7 Socket - Temperature Probe/ECo (immersion probe)

pin #

description

1

ECo (energy cut out) 24 VAC out (red wire)

2

Temperature Sensor (thermistor) +5.0 VdC (black wire)

3

Temperature Sensor (thermistor) -5.0 VdC (black wire)

4

ECo (energy cut out) 24 VAC return (red wire)

J9 Port - Communication Port - Not Used
J10 Socket - Not Used
J11 Port - Communication Port - Not Used
J13 socket - blower speed control

pin #

description

1

not used

2

not used

3

To 5 pin PWM wiring socket on Combustion Blower, see Figure 7 on page 11

4

not used

5

not used

6

not used

7

To 5 pin PWM wiring socket on Combustion Blower, see Figure 7 on page 11

8

To 5 pin PWM wiring socket on Combustion Blower, see Figure 7 on page 11

J15 Socket - Not Used
J16 Port - Communication Port - UIM Display (User Interface Module)

Advertising
This manual is related to the following products: