Wiring diagram, Muser interface module i u – State Industries SHE50-100PE User Manual

Page 46

Advertising
background image

44

Servicing should only be performed by a Qualified Service Agent

wiring diagram

2

GREEN

WHITE

RED

BLACK

1

1
2

BLACK

3

WHITE

COMBUSTION

BLOWER

TEMPERATURE PROBE

1 RED (ECO)

4 RED (ECO)

2 BLACK
3 BLACK

1 BLACK120 VAC HOT

3 WHITE 120 VAC NEUTRAL
4 YEL 24 VAC
4 YEL 24 VAC

HOT SURFACE IGNITER

FLAME SENSOR

BLOCKED

INTAKE AIR

BLOCKED

EXHAUST

BLOWER

PROVER

24 VOLT

GAS VALVE

B (CENTRAL CONTROL BOARD)

C

C

6J

5J
4J

7J

51

J

61

J

01

J

31

J

2J

3J

1J

TRANSFORMER

INSIDE CCB

ENCLOSURE

50VA

GROUND STRIP

BURNER GROUND

(BURNER BOLT)

ON/OFF

SWITCH

GROUND

120 VAC NEUTRAL

120 VAC HOT

1 BLACK
2 WHITE

RED

1 BLACK
2 WHITE

M

USER INTERFACE MODULE

I

U

2

15

4

14

5

10

6

7

8

11

L

N

1 4 5

3 WHITE/GREEN

7 WHITE/BLUE

8 WHITE/BROWN

2 RED
GREEN

WHITE

N

OI

T

C

N

UJ

X

O

B

N

E

E

R

G

N

E

E

R

G

ENABLE/DISABLE CIRCUIT

JUMPER WIRE BETWEEN PINS

8 AND 11 ON J6 PLUG

NOTE: COMBUSTION BLOWER

ASSEMBLY CONSISTS OF

MOTOR, BLOWER AND INTEGRAL

BLOWER SPEED CONTROL.

PWM (Pulse Width Modulation)

SPEED INSTRUCTION SIGNAL

WIRES FROM CCB TO BLOWER

SPEED CONTROL

120 VAC 1 Ø POWER

Figure 42

Service Notes:
This water heater is polarity and ground sensitive. The Control System will lock out and display the AC

Reversed fault message if the power supply polarity is reversed. Flame sensing current cannot be established

if the Burner is not grounded which will cause Ignition Failure fault conditions and Control System lock outs.

See Electrical Requirements on page 6.

Advertising
This manual is related to the following products: