State Industries SHE50-100PE User Manual

Page 40

Advertising
background image

38

Servicing should only be performed by a Qualified Service Agent

uim ribbon cable connection
Service Notes:
The Ribbon Cable that connects the Button Pad overlay to the uIM Circuit Board must be plugged in exactly

as shown in Figure 36 on page 37. The metal crimp connections in the Ribbon Cable plug must be facing away

from the uIM circuit board. These metal crimp connections are only visible on one side of the plug, see Figure

37 below. There are six flat metal pins on the uIM circuit board J3 socket. Ensure all six pins are fully inserted

into the Ribbon Cable plug whenever removing or installing the uIM or the Button Pad overlay.
It is possible to connect the Ribbon Cable Plug incorrectly. It can be plugged in upside down (with the crimp

connections facing the circuit board) or it can be plugged in with less than all six of the J3 socket pins inserted

into the plug.
Failure to connect this Ribbon cable exactly as shown Figure 36 on page 37 when servicing will render the

user input buttons inoperable. This should be checked whenever the nature of the service complaint is an

inoperable or unresponsive Control System display, uIM, or user input buttons, See uIM Is Inoperable on

page 57

RIBBON CABLE PLUG END

METAL CRIMP

CONNECTIONS

FRONT SIDE

BACK SIDE

Figure 37

Advertising
This manual is related to the following products: