Servicing should only be performed by a Qualified Service Agent

pressure switches

The water heaters covered in this manual are factory equipped with three pressure switches. Figure 4 on

page 9 shows the location of the three pressures switches on top of the water heater. This section of the

manual covers pressure switch construction, operation and the test procedures used to diagnose operational

problems associated with pressure switches.
construction & operation
Pressure switches activate in response to changes in pressure they sense through a plastic sensing tube

connected to sensing ports on the water heater, see Sensing Tubes on page 30.
A diaphragm divides the body of a pressure switch into two chambers. The chamber the sensing port is

attached to is sealed. The other chamber is vented to the atmosphere which allows the diaphragm to move

up and down. There is linkage that attaches the switch contacts to the diaphragm so that when the diaphragm

moves the contacts are activated, see Figure 30 below.
Activate means to change from the normal state. If the contacts are normally open, activating the contacts

will cause them to close. If the contacts are normally closed, activating the contacts will cause them to open.

Vent Port

Sensing Port

Flexible Diaphragm

Wiring Terminals

Switch Contacts

Normal State

(open switch contacts)

Activated State

(closed switch contacts)

Internal Linkage

Normal State

Activated State

Blower Prover

Pressure Switch

Normally open contacts,

close on a rise in pressure .

Blocked Exhaust

Pressure Switch

Normally closed contacts,

open on a rise in pressure .

Blocked Intake Air

Pressure Switch

Normally closed contacts,

open on a fall in pressure .

CONSTRUCTION

TYPES AND APPLICATION

Figure 30