Figure 16 figure 17 – State Industries SHE50-100PE User Manual

Page 19

Advertising
background image

17

Servicing should only be performed by a Qualified Service Agent

burner assembly installation
17. To re-install the Burner Assembly follow the steps for removal in reverse order.
18. Install a new white fiber gasket between the Burner Adapter and the Heat Exchanger Flange on top of

the water heater. Install a new white fiber gasket between the Burner and the Burner Adapter also. See

Figure 5 on page 9.

19. do not overtighten the 5/16 inch hex head machine screws holding the Burner to the Burner Adapter or

the 1/2 inch nuts that hold the Burner Adapter to the Heat Exchanger Flange on top of the water heater

storage tank.

20. Restore power to the water heater and run it through at least one complete heating cycle before leaving

to ensure it is operating properly.

FOUR 1/2 INCH

NUTS AND STUDS

BURNER

GROUND

WIRE

BURNER SIGHT GLASS

WIRING HARNESS COVER

PLATE AND GASKET.

TWO PHILLIPS HEAD

SCREWS HOLD COVER

PLATE AND GASKET IN

PLACE.

Figure 16

Figure 17

Advertising