Sanyo PLC-WXE46 User Manual

Page 15

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

15/65

8. Functional Execution Command

8.1 Format

1.

PC issues commands in format as below:

Pattern1 : “CF_COMMAND” [CR]

Pattern2 : “CF_COMMAND_”%1 [CR]

CF_

: Header

COMMAND : Character line

%1 : Parameter (Character line)

_ : Space (To separate COMMAND and Parameter)

2.

The projector decodes the received command and when it is ready to receive the next

command, it returns the response.

“000” [CR] : (0x06, 0x0D) When receiving Functional Execution Command

“nnn” [CR] : Except “000” , when it is unable to execute command by any specific reason.

See Error Code Table for details

3.

When the received data cannot be decoded, the projector returns “?” [CR]

8.2 Transfer Example

When setting projector’s total dots to 1344 by Expand Serial Command

PC

→ PJ: ”CF_TDOTS_1344” [CR]

PC

← PJ: “000”[CR] - - - - - - - - - - - Acceptable

8.3 Operation Requirements

Functional Execution Command is limited when the projector status is as below.

However, Status Read Command is effective even under these conditions.

Projector Status

Available Functional Execution Command

Standby Mode

C00: POWER ON

Countdown in process

C00: POWER ON
(Terminates Countdown)
C01: POWER OFF
C02: POWER OFF
(Terminates Countdown)

Cooling down in process

N/A

Cooling down in process due to Abnormal
Temperature

N/A

Abnormal Temperature

N/A

Power Failure
(For 60 seconds after Power Failure occurred)

N/A

Power Save / Cooling down in process

N/A

Power Save in process

C00: POWER ON
C01: POWER OFF

Note:) When the projector receives the other command in this above status, it returns error code

to show the status.

When the projector receives the following functional execution commands, OSD menu is closed

except for pop-up menu

Advertising