8.8 Lamp Command

8.8.1

CF_LAMPH Command

Command “CF_LAMPH_%1”[CR]

%1

“RST”

Details

Reset total lamp running time
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

8.8.2

CF_LAMPMODE Command

Command “CF_LAMPMODE_%1”[CR]

%1

“NORMAL” ------- Set lamp to Normal mode status
“ECO” ------------- Set lamp to ECO mode status
“UP” --------------- Switch Lamp mode forward.
(NORMAL

ECO

NORMAL

)

“DN” --------------- Switch Lamp mode in negative order
(ECO

NORMAL

ECO

)

Details

Select Lamp Mode
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]