Sanyo PLC-WXE46 User Manual

Page 54

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

54/65

9.9.5

CR_LAMPMSTS Command

Command “CR_LAMPSTS”[CR]

Details

Get Lighting status of lamp

Response

Acceptable

“000_%1”[CR]

%1

**** ” A number of * should be among 1-4.

First character shows how many lamps are incorporated in
projector. (1,2 or 4 )

Secound character shows follwing status in order of lamp number.

“I” Lamp is ON
“O” Lamp is OFF
“X” Lamp failure

e.g.
“1I”

1 Iamp model and Lamp is ON

“2IO

2 lamps model and No.1 Lamp is ON and No.2Lamp

is OFF

“4IOXI”

4 lamps model and No.1,No.4 lamps are ON. No.2

lamp is OFF and No.3 model is failed.

Unacceptable “Error Code”[CR]

9.9.6

CR_PROJH Command

Command “CR_PROJH”[CR]

Details

Get total running time of Projector by hour (h)

Response

Acceptable

“000_%1”[CR]

%1

“0000000”~“0099999”

Unacceptable “Error Code”[CR]

9.9.7

CR_HMLAMP Command

Command “CR_HMLAMP”[CR]

Details

Get lamp number.

Response

Acceptable

“000_%1”[CR]

%1

“001”

Unacceptable “Error Code” [CR]

Advertising