Sanyo PLC-WXE46 User Manual

Page 57

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

57/65

9.11.5 CR_CEIL Command

Command “CR_CEIL” [CR]

Details

Get setting status of Ceiling

Response

Acceptable

“000_%1”[CR]

%1

“ON” ------------------------------ Ceiling is ON
“OFF” ----------------------------- Ceiling is OFF

Unacceptable “Error Code” [CR]

9.11.6 CR_REAR Command

Command “CR_REAR” [CR]

Details

Get setting status of Rear

Response

Acceptable

“000_%1”[CR]

%1

“ON” ------------------------------ Rear is ON
“OFF” ----------------------------- Rear is OFF

Unacceptable “Error Code” [CR]

9.11.7 CR_SCREENASPECT Command

Command “CR_SCREENASPECT”[CR]

Details

Get setting status of Screen aspect

Response

Acceptable

“000_%1”[CR]

%1

“43MODE” ------------ 4:3 mode is selected.
“169MODE” ---------- 16:9 is selected.
“1610MODE” -------- 16:10 is selected.

Unacceptable “Error Code”[CR]

9.11.8 CR_TERMINAL Command

Command “CR_TERMINAL”[CR]

Details

Get setting status of Terminal

Response

Acceptable

“000_%1”[CR]

%1

“COMPUTER” ------------------ Computer input is seleted
“MONITOR” --------------------- Monitor out is setected.

Unacceptable “Error Code”[CR]

9.11.9 CR_INPUTSEARCH Command

Command “CR_INPUTSEARCH”[CR]

Details

Get setting status of Input search

Response

Acceptable

“000_%a”[CR]

%a

“OFF” --------------------- Input search is OFF
“ON1” --------------------- Input search is On1
“ON2” --------------------- Input search is On2

Unacceptable “Error Code”[CR]

Advertising