PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

49/65

9.7.5

CR_SRCINP3 Command

Command "CR_SRCINP3” [CR]

Details

Get selected source of Input 3_Video

Response

Acceptable

“000_%1”[CR]

Request data

“AUTO” -------------- Video Auto is selected
“VIDEO” ------------- Composite Video Input is selected
“S

VIDEO” -------- S-Video Input is selected

Unacceptable “Error Code”[CR]

9.7.6

CR_SYSTEM Command

Command “CR_SYSTEM”[CR]

Details

Get selected System

Response

Acceptable

“000_%1”[CR]

%1

Input is

PC Analog

“VGA1” -------------- VGA1 is selected
“VGA2” -------------- VGA2 is selected

“XGA1”-------------- XGA1 is selected

“WXGA3” --------- WXGA3 is selected
“1080i” ------------ 1080i is selected
“1035i” ------------ 1035i is selected
“720p” ------------- 720p is selected
“575p” ------------- 575p is selected
“480p” ------------- 480p is selected
“575i” -------------- 575i is selected
“480i” -------------- 480i is selected
“MODE1” ------- Mode1 is selected

“MODE5” -------------- Mode5 is selected
When there is no signal, projector returns error code”101”
[CR]

Input is

Y,Pb/Cb,Pr

/Cr

“AUTO” ----------- Auto is selected
“1080i” ------------1080i is selected
“1035i” ------------ 1035i is selected
“720p” ------------- 720p is selected
“575p” ------------- 575p is selected
“480p” ------------- 480p is selected
“575i” -------------- 575i is selected
“480i” -------------- 480i is selected
Projector returns selected System status regardless of the
signal input.

Input is

Video,S-Vi

deo

“AUTO” --------------- Auto is selected
“NTSC” --------------- NTSC is selected
“NTSC443” ---------- NTSC4.43 is selected
“PAL” ------------------ PAL is selected
“SECAM” ------------- SECAM is selected
“PAL

M” ------------- PAL-M is selected

“PAL

N” ------------- AL-N is selected

Projector returns selected System status regardless of the
signal input.

Unacceptable

““Error Code”[CR]