Sanyo PLC-WXE46 User Manual
Page 47
PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
47/65
9.6 Video Status Read Command
9.6.1
CR_SERSYS Command
Command “CR_SERSYS”[CR]
Details
Get currently selected signal
Returns auto-detected signal in Auto mode
Only available for Video input. (N/A when Input is computer)
Response
Acceptable
“000_%a”[CR]
%a
“1080I60” -------------- 1080i 60Hz
“1080I50” -------------- 1080i 50Hz
“1035I”. ---------------- 1035i
“720P” ------------------ 720p
“575P” ------------------ 575p
“480P” ------------------ 480p
“575I” ------------- 575i (includes Composite signal such as PAL)
“480I” ------------- 480i (includes Composite signal such as NTSC)
“NO_SIGNAL” --------------- There is no signal
Unacceptable
“101”[CR] -------- When Input for PC is selected
“Error Code”[CR]