Expand Serial Command Functional Specifications

9/65

3.

Notes for communication

1. Expand Serial Command is defined as one command / one line that starts with “C” and ends

with carriage return (0x0D)

2. There are two types of commands: Functional Execution Command and Status Read

Command.

- Example of Functional Execution Command:”CF_BRIGHT_032”[CR]

- Example of Status Read Command: “CR_RIGHT”[CR]

Note) ”_” means a space

3. When it takes more than one second to receive one command, it is not executed.

When it takes more than one second to receive carriage return (0X0D) after the projector

receives the first data “C”, it clears the information of buffer.

4. On command pipelining, wait for the interval of 100ms till sending next command after receiving

a response.

(More than 100ms)

Command

PC

→ Projector

“CF_BRIGHT_032” CR

Next Command

Projector

→ PC

“000” CR

Response

(A few ms - 5s)

When a computer sends next command before receiving a response, the projector may not operate

properly,except when there is no response for more than 5 seconds.

5. It takes about 5 seconds for internal initialization after plugging in AC power. During this time

commands cannot be processed. Do not issue any command.

4. Name Definition

1.

Data from a controller to a projector is represented as COMMAND, and data from a projector to

a controller for the incoming command is represented as RESPONSE.

2.

[CR] : Carriage Return Code

Command ends with cartridge return code.

Response also ends with carriage return code.

3.

_ : Space Code

A space Code is indicated by (_).

4.

%1 : Parameter in Command

When there are several parameters, they are defined as %2, %3…

5.

%%% : Error code returned from a projector

Acceptable: “000”.

Unacceptable: See [7. Error Code Table].

6.

%a : Parameter in Response Command

When there are several parameters, they are defined as %b, %c…

Advertising