Sanyo PLC-WXE46 User Manual

Page 23

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

23/65

8.6 Input Control Command

8.6.1

CF_INPUT Command

Command “CF_INPUT_%1”[CR]

%1

“CONPUTER1” ----- Select Computer1 Input
“COMPUTER2” ----- Select Computer2 Input
“VIDEO” --------------- Select Video Input
“UP” ------------------- Switch Input setting forward
When Computer 2 is selected in Terminal menu:

Computer1

→ Computer2 → Video →Computer1 → …

When Monitor out is selected in Terminal menu:

Computer1

→ Video →Computer1 → …

“DN” -------------------Switch Input setting backward
When Computer 2 is selected in Terminal menu:

Video

→ Computer2 →Computer1→S-video….

When Monitor out is selected in Terminal menu:

Video

→Computer1→….

Details

Select Input
The same operation as “INPUT” button of the Remote Control.
This command is available in normal Power ON status.

Note1) Projector returns “101” by selecting Computer 2 while Monitor out is
selected in Terminal menu.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

8.6.2

CF_SOURCE Command

Command “CF_SOURCE_%1”[CR]

%1

Input is

Computer 1

“ANALOG” --------- Select Analog Input
“YPBPR” ----------- Select Component Input
“SCART” ----------- Select Scart Input
”UP” ---------------- Switch Input as follows
Analog

→YPBPR →Scart →…

”DN” ---------------- Switch Input as follows
Scart

→YPBPR →Analog →…

Input is

Computer 2

“ANALOG” --------- Select Analog Input
”UP”
”DN”
Although no operation is made, projector accepts parameter ”UP”
/”DN”

Input is Video

“AUTO” -------------- Select Video Auto mode
“VIDEO” ------------- Select Composite Video Input
“S

VIDEO” -------- Select S-Video Input

”UP” ------------------ Switch Input as follows
Auto

→ Video → S-video → Auto…

”DN” ------------------ Switch Input as follows
S-video

→ Video → Auto → S-video…

Details

Select Source of currently selected Input
When Input specified by %1 is inappropriate for selected Input, the projector
returns “101” and the command is not executed.
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

Advertising