Sanyo PLC-WXE46 User Manual

Page 62

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

62/65

9.12 Other Status Read Command

9.12.1 CR_STATUS Command

Command “CR_STATUS”(CR)

Details

Get status of Projector behavior.
This command affects the same as ”CR0” of Basic Serial command, but this has
an error code.

Response

Acceptable

“000_%1”[CR]

%1

“00”= Power ON
“80”= Stand by
“40”= Count down
“20”= Cooling down
“10”= Power failure
“28”= Cooling down due to abnormal temperature
“88”= Stand by after Cooling down
“24”= Power saving cooling down
“04”= Power saving
“21”= Cooling down due to Lamp failure
“81”= Stand by after Cooling down due to Lamp failure

Unacceptable “Error Code”[CR]

9.12.2 CR_SIGNAL Command

Command “CR_SIGNAL”(CR)

Details

Get Signal status if there is signal or not

Response

Acceptable

“000_%a”[CR]

%a

“ON” ------------------------ Signal is found
“OFF” ----------------------- There is no signal

Unacceptable “Error Code”[CR]

9.12.3 CR_VMUTE Command

Command “CR_VMUTE”[CR]

Details

Get setting status of No Show

Response

Acceptable

“000_%a”[CR]

%a

“ON” -------- No Show is ON, User Logo (My picture) is displayed
“OFF” ------- No Show is OFF

Unacceptable “Error Code”[CR]

9.12.4 CR_FREEZE Command

Command “CR_FREEZE”[CR]

Details

Get setting status of Freeze

Response

Acceptable

“000_%a”[CR]

%a

“ON” ---------------------- Freeze is ON
“OFF” --------------------- Freeze is OFF

Unacceptable “Error Code”[CR]

Advertising