Sanyo PLC-WXE46 User Manual

Page 8

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

8/65

1. Overview

1.1 This Functional Specification defines communication functions for PLC-WXE46/WXL46

1.2 Compatible to Firmware Ver. 1.x of the projector.

1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the

commands are defined as Expand Serial Commands.

2. Serial Interface Specification

2.1 Transfer Specification

Item

Specification

Synchronous System Asynchronous

Transmission Speed

9600 / 19200

Data Length

8 bit

Parity

N/A

Stop Bit

1

Flow Control

N/A

Note1) Transmission Speed : initial setting value is 19200

Note2) Transmission Speed can be changed in service mode.

2.2 Connection

Dedicated serial cable must be used for a connection to a computer and a projector.

PC

Projector

COM 1

Control Port

(D-Sub 9 Pin) (Mini 8 Pin)

Advertising