TROUBLESHOOTING & REPAIR

F-67

F-67

INVERTEC® STT® & STT® II

CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)

FIGURE F.31 – PLUG J1 DISCONNECTION

LOWER

TRAY

AREA

OUTPUT CHOKE/
IGBT MODULE
SPLICED CONNECTION

J1 CURRENT
SENSING PLUG

5. Disconnect the current sensing plug J1 from

the control PC board. Carefully remove plug
J1 and associated leads from the control PC
board compartment.

FIGURE F.32 – PLUG J22 DISCONNECTION

PLUG J22

6. Locate and disconnect plug J22 from the

wiring harness. See Figure F.32.