A-6

INSTALLATION

A-6

INVERTEC® STT® & STT® II II

FIGURE A.2 RECONNECT PANEL

INPUT VOLTAGE RECONNECT
PROCEDURE

As shipped from the factory, multiple voltage machines
are internally configured for the highest input voltage
(440-460 VAC), for Codes 11092 and below and (380-
415 VAC), for Codes 11115 and 11116.

1. For Connections to 440 or 460 VAC verify the inter-

nal configurations to the procedures shown below
and refer to Figure A.2.

2. For Connections to 200,208,220,230,380,400 or

415 VAC follow the procedure shown below and
refer to figure A.2.

NOTE: Turn main power to the machine OFF

before performing the reconnect procedure.
Failure to do so will result in damage to the
machine. DO NOT switch the reconnect bar with
machine power ON.

------------------------------------------------------------------------

To Operate at

Procedure

460 or 440 VAC

1. Open reconnect panel

(Codes 11092 and

access door on wrap-

around.
below)

2. Move input voltage switch

to Voltage = 380 -460V pos-
ition.

3. Move lead “A” to 440-460

Terminal.

380 or 415 VAC

1. Open reconnect panel

(Codes 11092 and

access door on wrap-

around.
below)

2. Move input voltage switch

to Voltage = 380-460V
position.

3. Move lead “A” to 380-415

Terminal.

380,400 or 415 VAC

1. Open reconnect panel

(Codes 11115 and

access door on wrap-

around.
11116)

2. Move input voltage switch

to Voltage = 380-460V
position.

3. Move lead “A” to 380-415

Terminal.

220 or 230 VAC

1. Open reconnect panel

(Codes 11092 and

access door on wrap-

around.
below)

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead “A” to 220-230

Terminal.

200 or 208 VAC

1. Open reconnect panel

(Codes 11092 and

access door on wrap-

around.
below)

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead “A” to 200-208

Terminal.

200 or 208 VAC 1. Open reconnect panel
(Codes 11115 and

access door on wrap-around.

11116)

2. Move input voltage switch

to Voltage = 200 -230V
position.

3. Move lead “A” to 200-208

Terminal.

OUTPUT CONNECTIONS

WIRE FEEDER OUTPUT CONNECTIONS

Refer to the Accessories section of this manual for
instructions on connecting a wire feeder to the Invertec
STT II.

The LN-742 or STT-10 wire feeder is the recommend-
ed feeder for use with the Invertec STT II.

WARNING

4A

380-415

380-415
OR

OR

OR

OR

200

200--208

208

*

*

*

(NOT PRESENT ON ALL MODELS)

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising