Troubleshooting & repair, Input rectifier test (continued), Ca 9 12 b – Lincoln Electric INVERTEC SVM129-B User Manual

Page 64: Warning

Advertising
background image

TROUBLESHOOTING & REPAIR

F-26

F-26

INVERTEC® STT® & STT® II

INPUT RECTIFIER TEST (continued)

FIGURE F.9 - INPUT RECTIFIER LOCATION

INPUT
RECTIFIER

C

A

9

12

B

TEST PROCEDURE

1. Turn off the INVERTEC® STT® & STT® II

and disconnect main AC input power to the
machine.

2. Using the 5/16" nut driver, remove the case

wraparound cover.

3. Perform the Input Filter Capacitor

Discharge

procedure.

See

the

Maintenance section.

ELECTRIC SHOCK can
kill.

• Before continuing with

the test procedure, per-
form the capacitor dis-
charge procedure to
avoid electric shock.

4. Locate the input rectifier. See Figure F.9.

5. Locate the leads needed to perform the

tests. See Figure F.9.

6. Use an ANALOG ohmmeter to perform the

tests shown in Table F.3.

WARNING

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising