TROUBLESHOOTING & REPAIR

F-69

F-69

INVERTEC® STT® & STT® II

CAPACITOR REPLACEMENT

NOTE: Capacitors must always be replaced in

matched sets (C1 and C2 as a set).

When replacing Capacitors, remove the entire
FET heat sink assembly, including the capacitors
and switch board, as a unit.

Disassemble and reassemble only one unit at a
time. Use the other unit as a model during
reassembly so that all parts are reinstalled prop-
erly.

14. Remove the two 3/8” hex head nuts from the

top of the through-bolts. The hex nuts are
located on top of the fan shroud. See Figure
F.34.

CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)

FIGURE F.34 – REMOVING HEX HEAD NUTS OF THROUGH-BOLTS

HEX NUT