TROUBLESHOOTING & REPAIR

F-5

F-5

INVERTEC® STT® & STT® II

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

Machine has no welding output (no
open circuit voltage), and the wire
feeder does not feed wire when the
gun trigger is pulled.

1. The 42VAC circuit breaker CB1

may be tripped. Reset if neces-
sary.

2. Check the 4 amp slow blow fuse

located on the reconnect panel.
Replace if faulty.

3. Put a jumper between pins "A"

and "C" on the 5 pin amphenol
located on the LN-742 wire
feeder. If wire feeds, check the
gun trigger. Repair or replace if
necessary.

4. Check for the presence of

42VAC at pins "K" and "I" on the
14 pin amphenol. If the 42VAC
is present and the feeder does
not work, the problem is in the
feeder control cable or the wire
feeder.

1. If 42VAC is NOT present at pins

"K" and "I" on the 14 pin amphe-
nol, perform the T1 Auxiliary
Transformer Test.

2. Check leads #43 and #212C for

loose or faulty connections
between the T1 auxiliary trans-
former and the remote protec-
tion board. See the Wiring
Diagram. Also check the conti-
nuity through the remote protec-
tion board to the 14 pin amphe-
nol. See the Remote Protection
Board Schematic.